Brand Name : CNP NM FIRE
Model Number : SCF200-150-330
Certification : UL
Place of Origin : China
MOQ : 1set
Price : Negotiation
Payment Terms : L/C, T/T
Delivery Time : 60 Days
Packaging Details : Export Packing
CAPACITY : 2000GPM
HEAD : 75-125METER
Driving Mode : Diesel Engine Driver
Controller : Tornatech (UL/FM)
RPM : 2950
Diesel Engine : M6-108E
| Pump | Engine | Controller | Jockey Pump Set | ||
| Brand | NM Fire Split Case | NMFIRE | Tornatech | NM FIRE | Tornatech | 
| Mdele | SCF200-150-330 | NM6-108E | GPD | CDL2-15 | |
| Detail | 
 Material: | 250kw at 2950rpm | / | / | |
Industrial fields: All petroleum, petrochemical, chemical, oil fields, pipelines bureaus, oil repositories, oil terminals, oil refineries, offshore platforms, etc.; National grain storages, thermal power plants, steel plants, shipyards, paper mills, etc.;
  Commercial Field: five-star hotels, hospitals, schools, supermarkets, office buildings, large-scale commercial complex, highway tunnels, subway stations, railway stations, airports; Fire-fighting Engineering Companies;
Please note :the pump will be not sold individual,it must be match with engine or electric motor driver.
Please contact us if you have any other requirements.
Thanks


  

CNP was founded more than 25 years,At the beginning, CNP focused on the research and development of stamping and welding stainless steel centrifugal pumps.
Now CNP is the second largest manufacturer on the stainless steel centrifugal pump in the world.
CNP Headquarter :300,000 m2
Over 30 Subsidiaries
More than 5000 staffs
| The subsidiary corporations is as follows: | |
| Manufacturing | Environmental protection | 
| •NANFANG PUMP INDUSTRY CO., LTD. •HANGZHOU NANBENG ENERGY-SAVING TECHNOLOGY Co. Ltd •HUZHOU NANFENG MACHINARY MANUFACTURING Co. Ltd •CNP CHANGSHA Co., Ltd. •CNP NM FIRE FIGHTING SYSTEM CO.,LTD •HANGZHOU CNP-TSURUMI PUMP CO.,LTD •HANGZHOU HOWELL FLOW Co., Ltd. •NANFANG INDUSTRY PTE. LTD. •TIGERFLOW SYSTEM LLC | •JINSHAN ENVIROMENTPROTECTION SCIENCE and TECHNOLOGY CO.,LTD •BEIJING ZHONGZIHUAYU ENVIRONMENTAL TECHNOLOGY CO.,LTD | 
CNP and NM Fire set up a cooperative enterprise in October,2013. introducing some experienced talents with international first-class technical level. The designation and production of the products are strictly consistent with requirements of international certificates,for changing the backward conditions in domestic market.
NM Fire is the first member of NFPA from Chinese pump manufacturers. In March of 2017, it became the first enterprise of China to have both UL & FM two international certification of fire pumps. In September the same year, NM Fire again became the China’s first enterprise to have UL certificate for diesel fire engine. Currently, only 3 or 4 companies in the world have obtained fire engine certification. NM Fire is also the first company in the world to have both UL Listed fire pumps and fire engines. This series of achievements will completely break the long-term monopoly situation of fire products by European and American brand, which speed up the pace of Chinese enterprises to go overseas.

End suction Pump Model Chart
| Rated Capacity | PUMP MODEL(UL) | Rated Net Pressure Range, | Approx. Speed, | Impeller Diameter, mm. | |
| GPM (US) | PSI | RPM | Max | Min | |
| 50 | ESF40/20 | 76-111 | 2980 | 225 | 190 | 
| 50 | ESF40/20 | 108-157 | 3550 | 225 | 190 | 
| 100 | ESF40/20 | 72-109 | 2980 | 225 | 190 | 
| 100 | ESF40/26 | 100-138 | 2980 | 264 | 225 | 
| 200 | ESF50/20 | 72-99 | 2980 | 225 | 195 | 
| 200 | ESF50/20 | 102-142 | 3550 | 225 | 195 | 
| 200 | ESF50/26 | 105-140 | 2980 | 264 | 230 | 
| 250 | ESF50/20 | 69-99 | 2980 | 225 | 195 | 
| 250 | ESF50/20 | 101-141 | 3550 | 225 | 195 | 
| 250 | ESF50/26 | 99-136 | 2980 | 264 | 230 | 
| 250 | ESF65/20 | 113-152 | 3550 | 225 | 195 | 
| 250 | ESF65/20 | 86-107 | 2980 | 225 | 210 | 
| 250 | ESF65/26 | 119-147 | 2980 | 264 | 245 | 
| 300 | ESF65/20 | 112-152 | 3550 | 225 | 195 | 
| 300 | ESF65/20 | 86-107 | 2980 | 225 | 210 | 
| 300 | ESF65/26 | 119-147 | 2980 | 264 | 245 | 
| 400 | ESF65/20 | 108-150 | 3550 | 225 | 195 | 
| 400 | ESF65/20 | 83-104 | 2980 | 225 | 210 | 
| 400 | ESF65/26 | 119-141 | 2980 | 264 | 245 | 
| 450 | ESF65/20 | 105-148 | 3550 | 225 | 195 | 
| 450 | ESF65/20 | 80-102 | 2980 | 225 | 210 | 
| 450 | ESF65/26 | 114-138 | 2980 | 264 | 245 | 
| 500 | ESF65/20 | 101-145 | 3550 | 225 | 195 | 
| 500 | ESF65/20 | 77-99 | 2980 | 225 | 210 | 
| 500 | ESF65/26 | 111-135 | 2980 | 264 | 245 | 
| 500 | ESF80/20 | 90-100 | 2980 | 225 | 210 | 
| 500 | ESF80/20 | 129-142 | 3550 | 225 | 210 | 
| 500 | ESF80/26 | 116-138 | 2980 | 264 | 245 | 
| 750 | ESF80/20 | 87-98 | 2980 | 225 | 210 | 
| 750 | ESF80/20 | 127-142 | 3550 | 225 | 210 | 
Split casing Pump Model Chart
| Rated Capacity | Model Designation | Rated Net Pressure Range, | Approx. Speed, | Maximum Working Pressure, | Impeller Diameter, mm. | |
| GPM (US) | PSI | RPM | PSI | Max | Min | |
| 300 | SCF125-100-300 | 123-195 | 2980 | 400 | 315 | 250 | 
| 400 | SCF125-100-300 | 120-189 | 2980 | 400 | 315 | 250 | 
| 400 | SCF125-100-300 | 173-274 | 3550 | 400 | 315 | 250 | 
| 450 | SCF125-100-300 | 119-187 | 2980 | 400 | 315 | 250 | 
| 450 | SCF125-100-300 | 172-272 | 3550 | 400 | 315 | 250 | 
| 500 | SCF125-100-300 | 117-184 | 2980 | 400 | 315 | 260 | 
| 500 | SCF125-100-300 | 170-269 | 3550 | 400 | 315 | 260 | 
| 750 | SCF125-100-300 | 104-163 | 2980 | 400 | 315 | 260 | 
| 750 | SCF125-100-300 | 157-247 | 3550 | 400 | 315 | 260 | 
| 750 | SCF125-80-350G | 169-251 | 2980 | 261 | 330 | 280 | 
| 750 | SCF150-100-320 | 138-198 | 2980 | 202 | 300 | 255 | 
| 1000 | SCF150-100-320 | 130-191 | 2980 | 202 | 300 | 240 | 
| 1000 | SCF200-150-310 | 119-237 | 2980 | 350 | 335 | 240 | 
| 1000 | SCF200-150-310 | 175-253 | 3550 | 350 | 290 | 240 | 
| 1250 | SCF200-125-300 | 116-190 | 2980 | 187 | 300 | 240 | 
| 1250 | SCF200-125-380 | 118-177 | 2200 | 261 | 385 | 325 | 
| 1250 | SCF200-150-310 | 112-230 | 2980 | 350 | 335 | 240 | 
| 1250 | SCF200-150-310 | 168-247 | 3550 | 350 | 290 | 240 | 
| 1500 | SCF200-150-310 | 158-236 | 3550 | 350 | 290 | 240 | 
| 1500 | SCF200-150-460 | 115-181 | 1800 | 275 | 460 | 380 | 
| 2000 | SCF200-150-460 | 118-175 | 1800 | 275 | 460 | 395 | 
| 2000 | SCF250-200-350 | 123-239 | 2980 | 362 | 360 | 260 | 
| 2500 | SCF250-200-350 | 114-227 | 2980 | 362 | 360 | 260 | 
| 2500 | SCF250-200-430 | 138 | 1800 | 275 | 425 | n/a | 
| 2500 | SCF250-200-430 | 125-190 | 2100 | 275 | 425 | 360 | 
| 3000 | SCF250-200-430 | 144-187 | 2100 | 275 | 425 | 390 | 
| 3500 | SCF300-250-490 | 119-189 | 1800 | 290 | 490 | 410 | 
| 4000 | SCF300-250-490 | 114-185 | 1800 | 290 | 490 | 410 | 
| 4500 | SCF300-250-490 | 153-181 | 1800 | 290 | 490 | 460 | 
| 4500 | SCF400-350-640 | 129-196 | 1480 | 315 | 655 | 540 | 
| 5000 | SCF400-350-640 | 127-194 | 1480 | 315 | 655 | 540 | 
| 5500 | SCF400-350-640 | 124-192 | 1480 | 315 | 655 | 540 | 
| 6000 | SCF400-350-640 | 120-190 | 1480 | 315 | 655 | 540 | 
| 6500 | SCF400-350-640 | 116-186 | 1480 | 315 | 655 | 540 | 
| 7000 | SCF400-350-640 | 113-182 | 1480 | 315 | 655 | 540 | 
| 7500 | SCF400-350-640 | 109-179 | 1480 | 315 | 655 | 540 | 
Centrifugal Fire Pumps Vertical Tubine Model Chart
| Rated Capacity gpm | Model Dsg | Rated Net Pressure Range psi | Approx Speed rpm | Stages | 
| 1250 | 250VTP400-28 | 41-51 | 1480 | 1 | 
| 82-102 | 2 | |||
| 124-153 | 3 | |||
| 165-305 | 4-6 | |||
| 1500 | 40-49 | 1 | ||
| 77-97 | 2 | |||
| 115-292 | 3-6 | |||
| 1500 | 58-71 | 1760 | 1 | |
| 115-143 | 2 | |||
| 173-214 | 3 | |||
| 230-285 | 4 | |||
| 2000 | 63 | 1 | ||
| 125 | 2 | |||
| 188 | 3 | |||
| 251 | 4 | |||
| 2000 | 250VTP550-26 | 40-44 | 1480 | 1 | 
| 77-88 | 2 | |||
| 116-132 | 3 | |||
| 155-176 | 4 | |||
| 194-264 | 5-6 | |||
| 2000 | 57-66 | 1760 | 1 | |
| 113-133 | 2 | |||
| 170-199 | 3 | |||
| 227-266 | 4 | |||
| 2500 | 61 | 1760 | 1 | |
| 123 | 2 | |||
| 184 | 3 | |||
| 245 | 4 | |||
| 2500 | 300VTP860-43 | 50-82 | 1480 | 1 | 
| 100-245 | 2-3 | |||
| 3000 | 53-78 | 1 | ||
| 105-235 | 2 | |||
| 2500 | 350VTP860-43 | 74-118 | 1760 | 1 | 
| 149-236 | 2 | |||
| 3000 | 69-115 | 1 | ||
| 139-230 | 2 | |||
| 3500 | 73-111 | 1 | ||
| 146-222 | 2 | |||
| 4000 | 104 | 1 | ||
| 207 | 2 | 
In addition to the above models, there are many model UL/FM testing in process.
Looking forward to your enquiry.
  Q1.Do you have the UL-LISTED Fire Pump Sets?    Yes, We have the UL/FM and NFPA standard Fire Pump Sets.    Q2.I need your motor drive End-suction/Split-casing fire pump, what information shold I sent to you ?    Sir/Madam,you can privide the Capacity, Heed, Voltage and Frequncy,we will make the quotation for you,If you need Jockey Pump or other accessories, please tell us together.    Q3.If I need your Diesel Engine Drive End-suction/Split-casing fire pump, what information shold I sent to you ?    You can sent the Capacity Heed, Temperature and Altitude (temperature and altitude will affect the performance of diesel engines).If you need Jockey Pump or other accessories, please tell us Voltage and Frequncy or accessories together.    Q4.I need the UL/FM Vertical Tubine Fire Pump Set ,please sent me the price.    For the motor Diver Vertical Tubine Fire Pump Set: you shoul give us the Capacity, Heed, Voltage Frequncy and the tank deep.    For the Diesel Engine Drive Vertical Tubine Fire Pump Set:you should give us the Capacity, Heed and the tank deep.    If you need Jockey Pump or other accessories,please tell us together.    
1. Reply within 24 hours.
  2. High-quality products and the most reasonable price
  3. Data and chemical technology support.

|   | 
| Split Case Fire Pump With Tonatech Controller Centrifugal Fire Pump UL Listed Fire Pumps fire fighting pumps -000 Images | 
 UL / FM Non Listed Split Case Fire Pump Capacity 750 M3/H @ 105m Diesel Engine
                                                                                    
                        
                        
                        
                                                            UL / FM Non Listed Split Case Fire Pump Capacity 750 M3/H @ 105m Diesel Engine
                                                    
                        
                     CNP NM Fire Water Jockey Pump , High Speed Fire Water Pump Package UL NFPA20
                                                                                        
                                                        
                        
                        
                        
                                                            CNP NM Fire Water Jockey Pump , High Speed Fire Water Pump Package UL NFPA20
                                                    
                        
                     NFPA20 Horizontal Split Case Fire Pump For Schools / Supermarkets 1500gpm@300
                                                                                    
                        
                        
                        
                                                            NFPA20 Horizontal Split Case Fire Pump For Schools / Supermarkets 1500gpm@300
                                                    
                        
                     High Performance Split Case Fire Pump , Fire Fighting Water Pump 180kw Shaft
                                                                                    
                        
                        
                        
                                                            High Performance Split Case Fire Pump , Fire Fighting Water Pump 180kw Shaft
                                                    
                        
                     300~2500 GPM Horizontal Split Case Centrifugal Fire Pumps certified by UL/FM
                                                                                        
                                                        
                        
                        
                        
                                                            300~2500 GPM Horizontal Split Case Centrifugal Fire Pumps certified by UL/FM
                                                    
                        
                     Fire Fighting Double Suction Horizontal Split Case Pump 500 GPM UL Listed
                                                                                    
                        
                        
                        
                                                            Fire Fighting Double Suction Horizontal Split Case Pump 500 GPM UL Listed
                                                    
                        
                     750 GPM Electric Fire Fighting Pump / Fire Fighting Pump System 170PSI UL FM
                                                                                        
                                                        
                        
                        
                        
                                                            750 GPM Electric Fire Fighting Pump / Fire Fighting Pump System 170PSI UL FM
                                                    
                        
                     Diesel Engine Split Case Fire Pump With Electric Motor 1000 GPM
                                                                                    
                        
                        
                        
                                                            Diesel Engine Split Case Fire Pump With Electric Motor 1000 GPM
                                                    
                        
                     Single Stage Double Suction Centrifugal Fire Pump Split Case 500 GPM With 120
                                                                                    
                        
                        
                        
                                                            Single Stage Double Suction Centrifugal Fire Pump Split Case 500 GPM With 120
                                                    
                        
                     Electric Motor Diesel Engine Driven 8000GPM Horizontal Split Case Fire Pump
                                                                                        
                                                        
                        
                        
                        
                                                            Electric Motor Diesel Engine Driven 8000GPM Horizontal Split Case Fire Pump